December 2002 TOSHIBA TEC 7 - 25 e-STUDIO160/200/250 SCANNER
Fig. 7-8-22
Screw
Cable holder
Lamp cable
Carriage 1
13. Remove one screw and detach the ground wire.
14. Remove 2 screws, cut the cable tie, and de-
tach the exposure lamp.
Fig. 7-8-23
Screw
Exposure lamp
Screw
Cable tie
Ground wire
055-1
054-1
11. Loosen one screw securing cable holder and
release the lamp cable.
Notes: When installing the lamp cable, note the
following points:
1.When retaining the lamp cable with cable
holder, the mark of the lamp cable must
be at the edge of cable holder.
2.After installing the lamp cable, check that
carriage 1/carriage 2 is not lifted. If lifted,
secure it by moving the lamp cable front-
to-back.
12. Move carriage 1 to around the center.
Note: To move carriage 1, push both ends of car-
riage 1 as Fig. 7-8-22, or if you cannot reach
there, turn scanner drive shaft to move the
carriage.
Fig. 7-8-24
Screw
Carriage 1
Carriage 1
056-3
[G] Carriage 1/ mirror 1
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Detach top cover. (See Fig. 2-6-2)
6. Detach scanner cover. (See Fig. 2-6-3)