e-STUDIO160/200/250 SCANNER 7 - 24 December 2002 TOSHIBA TEC
Fig. 7-8-21
Screw
Connector
Ground wire
053-1
Screw
INV PWA
Connector
Ground wire
053-2
Fig. 7-8-20
Fig. 7-8-19
Screw
Screw
Screw
Screw
Scanner frame cover
052
e-STUDIO160
9. Remove INV PWA assembly.
(See Fig. 7-8-14) (for e-STUDIO200/250)
10. Detach the connector from INV PWA (CN2),
remove one screw, and detach the ground wire.
e-STUDIO200/250
[F] Exposure lamp
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Detach top cover. (See Fig. 2-6-2)
6. Detach scanner cover. (See Fig. 2-6-3)
7. Detach top cover L. (See Fig. 2-6-4)
8. Detach top cover R. (See Fig. 2-6-5)
9. Remove the 12 screws and detach scanner
frame cover.
Note: When attaching scanner frame cover, cor-
rectly fit the tab of scanner frame and
tighten the screws while keeping down
scanner frame cover. Tighten the screws
in the order of numbers. The unnumbered
screws may be tightened not in order.