e-STUDIO160/200/250 SCANNER 7 - 26 December 2002 TOSHIBA TEC
Fig. 7-8-26
JIG (wire)
Wire
Scanner
drive shaft
058-1
Fig. 7-8-25
Spring plate
Spring plate
Mirror 1
Spring plate
Adjusting screw
056-2
7. Detach top cover L. (See Fig. 2-6-4)
8. Detach top cover R. (See Fig. 2-6-5)
9. Release the lamp cable.
(See Fig. 7-8-19 to 7-8-22)
10. Loosen 2 screws, release wire, and remove car-
riage 1.
11. Remove spring plate securing mirror 1 and re-
move mirror 1.
Notes: 1. Clean the surface of mirror 1 if dirty.
2. For mounting Carriage 1 and adjusting
the distortion, refer to the Service Hand-
book. (See Chapter 1.8)
[CAUTION]
Never turn the angle adjusting screw of mirror. Be
careful that holding or pushing the lamp part can
damage the lamp.
[H] Carriage 2/mirror 2/mirror 3
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Detach top cover. (See Fig. 2-6-2)
6. Detach scanner cover. (See Fig. 2-6-3)
7. Detach top cover L. (See Fig. 2-6-4)
8. Detach top cover R. (See Fig. 2-6-5)
9. Release the lamp cable.
(See Fig. 7-8-19 to 7-8-22)
10. Remove carriage 1. (See Fig. 7-8-24)