December 2002 TOSHIBA TEC 7 - 21 e-STUDIO160/200/250 SCANNER
[C] Scanner motor
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Remove scanner assembly.
(See Fig. 7-8-1 to 7-8-6)
6. Remove original glass. (See Fig. 7-8-7)
7. Detach one connector and detach the motor
harness.
8. Remove one screw and remove the ADF con-
nector plate.
9. Release the clamp and detach the harness.
Fig. 7-8-9
044-1
Motor harness
Clamp
Screw
ADF
connector plate
Harness
Fig. 7-8-12
Screw
Scanner motor
Timing
belt 142
046-1
10. Remove 4 screws and remove scanner motor
assembly while releasing timing belt 157.
Fig. 7-8-11
Timing belt 157
Scanner motor
assembly
Screw
045-1
e-STUDIO160 series
Fig. 7-8-10
044-2
Motor harness
Clamp
Screw
ADF
connector plate
Harness
e-STUDIO200/250 series
Screw
11. Remove 2 screws and remove Scanner motor
while releasing scanner timing belt 142.
Notes: 1. For adjusting the timing belt when
mounting the scanner motor, refer to the
Service Handbook. (See Chapter 1.8)
2. Do not mix the screws removed.