e-STUDIO160/200/250 SCANNER 7 - 22 December 2002 TOSHIBA TEC
Fig. 7-8-13
CN1
CN2
049-6
Screw
INV PWA
assembly
5. Remove 2 screws, release 2 locking supports,
and remove INV PWA.
Fig. 7-8-15
Fig. 7-8-14
Fig. 7-8-16
Screw
Screw
Blind plate
050-6
[D] INV PWA
(e-STUDIO160 series)
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. Detach top cover. (See Fig. 2-6-2)
3. Detach 2 connector from INV PWA (CN1/CN2).
4. Remove one screw and remove clamp.
5. Release one locking support and remove INV
PWA assembly.
(e-STUDIO200/250 series)
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. Detach top cover. (See Fig. 2-6-2)
3. Detach 2 connector from INV PWA (CN1/CN2).
4. Remove 2 screws and remove INV PWA as-
sembly.
049-7
INV PWA
Screw
Locking
support
Screw
049-3
Screw
INV PWA
assembly
Connector
Connector
[E] Scanner PWA
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove original glass. (See Fig. 7-8-7)
3. Remove 8 screws and remove blind plate.
(e-STUDIO160 series)
4. Remove 6 screws and remove blind plate.
(e-STUDIO200/250 series)
Clamp
Connector Locking support