December 2002 TOSHIBA TEC 7 - 23 e-STUDIO160/200/250 SCANNER
Fig. 7-8-18
Scanner
PWA
Flexible cable
Connector
051-1
Scanner PWA
Screw
5. Detach all the connectors from scanner PWA.
Note: Route the flexible cable under scanner
PWA to avoid damage beforehand. When
attaching the flexible cable, securely lock
the connector locks on both sides of the
connector.
6. Remove 2 screws and remove scanner PWA.
Important: 1. After the replacement of the
scanner PWA, download firmware
for the scanner PWA. For details,
see chapter 5 of the Service
Handbook.
2. Download the MAIN PWA firmware,
if necessary, after confirming the
version of it.
3. After replacing the scanner PWA,
program 05-306, 304, and then
305, by referring to the Service
Handbook.
4. When the error message “F14”
appears after replacing the scanner
assembly, refer to the Service
Handbook and perform (08-389).
Note: When removing scanner PWA, beware of
scanner drive shaft.
Note: If the damp heater is installed, release one
hook and detach one connector.