December 2002 TOSHIBA TEC 14 - 21 e-STUDIO160/200/250 FUSER UNIT/PAPER EXIT UNIT
Harness
Clamp
Connector
Screw
Exit unit
Screw
038
[J] Exit unit
1. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate and junction block.
2. If a JSP (MJ-5001) or OCT (MJ-5002) is at-
tached to the copier, detach it.
3. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
4. Detach scanner cover. (See Fig. 2-6-3)
5. Detach control panel front cover.
(See Fig. 2-6-6)
6. Detach control panel bottom cover.
(See Fig. 2-6-7)
7. Detach ozone cover. (See Fig. 2-6-9)
8. Detach paper tray cover. (See Fig. 2-6-10)
9. Detach upper right cover R. (See Fig. 2-6-14)
10. Detach front frame cover F/R.
(See Fig. 2-6-18 and 2-6-19)
11. Detach exit cover. (See Fig. 2-6-20)
12. Remove one screw holding the top cover L.
(See Fig. 2-6-21)
13. Remove 2 screw holding the left cover R.
(See Fig. 2-6-21)
14. Detach inner cover. (See Fig. 2-6-21)
15. Detach the relay connector.
16. Remove 4 screws, release the clamp, and re-
move exit unit.
Note: If exit roller is found dirty, wipe off.
Fig. 14-7-39