TopAccess Error Messages 329
2D30
Failed to create directory Make sure that the access privilege to the
storage directory is writable and also the
disk in the directory has enough space,
and then retry the job. If more than one job
is performed simultaneously, the error may
occur because the disk temporarily runs
out of space. In this case, wait for a while
and retry the job. If the error still occurs,
turn the power OFF and then back ON,
and then retry it.
2D31, 2D33
Failed to create file Make sure that the access privilege to the
storage directory is writable and also the
disk in the directory has enough space,
and then retry the job. If more than one job
is performed simultaneously, the error may
occur because the disk temporarily runs
out of space. In this case, wait for a while
and retry the job. If the error still occurs,
turn the power OFF and then back ON,
and then retry it.
2D32
Failed to delete file Make sure that the access privilege to the
storage directory is writable and then retry
the job. If the error still occurs, turn the
power OFF and then back ON, and then
retry it.
2D40
Failed to convert image file format When this error occurs by converting the
Slim PDF format, retry the scan. If the
error still occurs, specify the general PDF
format.
When this error occurs by converting other
than the Slim PDF format, turn the power
OFF and then back ON. Then retry the
scan. If the error still occurs, contact your
service representative.
2D43
Encryption error. Failed to create file Retry the job in error. If the error still
occurs, turn the power OFF and then back
ON. Then retry it.
2D44
When the encryption PDF enforced mode
is set and an attempt to create an image
file not encrypted is made, it is not allowed.
Reset the encryption and perform the job
in error again.
If an image file not encrypted is created,
consult your administrators.
2D60
Failed to copy file Turn the power OFF and then back ON.
Retry the scan. If the error still occurs,
contact your service representative.
2D62
Failed to connect to network destination.
Check destination path.
Make sure the network folder is shared in
your network and retry the scan. If the
error still occurs, ask your administrator to
confirm whether the IP address or path of
the server is correct. Also make sure that
the server is operating properly.
2D63
Specified network path is invalid. Check
destination path.
Make sure you specify correct network
folder and retry the scan.