Motor Type
Program Motor Parameters Motor Settings
This parameter identifies the type of motor being used.
Settings:
0 — Toshiba EQP III TEFC
1 — Toshiba EQP III ODP
2 — Toshiba EPACT TEFC
3 — Toshiba EPACT ODP
4 — Other Motor
Direct Access Number — F413
Parameter Type — Selection List
Factory Default Toshiba EQP III
TEFC
Changeable During Run — No
Motor Constant 3 Enable
Program Motor Parameters Vector Motor Model
This parameter Enables/Disables tuning of Motor Constant 3 during an
Autotune.
Settings:
0 — Disabled
1 — Enabled (box checked)
Direct Access Number — F414
Parameter Type — Check Box
Factory Default Enable
Changeable During Run — No
Torque Command
Program Torque Setting Torque Control
When operating in the Torque Control mode, this parameter allows the user to
select the source of the torque command signal.
Settings:
1 — VI/II
2 — RR
3 — RX
4 — RX2 (option)
5 — CN8 Option (LED Keypad)
6 — Binary/BCD Input
7 — Common Serial (TTL)
8 — RS232/RS485
9 — Communication Card
Direct Access Number — F420
Parameter Type — Selection List
Factory Default RX
Changeable During Run — Ye s
Torque Command Filter
Program Torque Setting Torque Control
This parameter reduces the motor vibration caused by large-inertia loads. A
small value will have a great effect while an increased value will have a lesser
effect.
Direct Access Number — F421
Parameter Type — Numerical
Factory Default 200.0
Changeable During Run — Ye s
Minimum — 10.0
Maximum — 200.0