2 Troubleshooting  2.8 Display 
Check 3  The FL may be faulty.  Replace it with a new one and return to Procedure 
3.  If there is still an error, perform Check 4. 
Check 4  The FL inverter board may be faulty.  Replace it with a new one and 
return to Procedure 3.  If there is still an error, perform Check 5. 
Check 5  Make sure the LCD/FL cable has been firmly connected to the system 
board and LCD module. 
FL inverter board
System board
CPU
LCD/FL cable
 
 
  If the cable is loose or off, reconnect it firmly and return to Procedure 3.  
If there is still an error, perform Check 6. 
Check 6  The LCD/FL inverter cable may be faulty.  Replace it with a new one and 
return to Procedure 3.  If there is still an error, perform Check 7. 
Check 7  The LCD module may be faulty.  Replace it with a new one and return to 
Procedure 3.  If there is still an error, perform Check 8. 
Check 8  The System board may be faulty.  Replace it with a new one.  If there is 
still an error, perform Check 9. 
Check 9  The memory may be defective. Replace the memory module with a new 
one following the steps described in Chapter 4. If the problem persists, 
perform Check 10. 
Check 10  The CPU may be faulty.  Replace it with a new one following the 
instructions in Chapter 4. 
 
2-20  Satellite/Satellite Pro/A500/A505/A507/dynabook     Maintenance Manual