STE 80897
– 2–10
TRANSPORTATION & INSTALLATION MANUAL
2.3.4 Cautions on Direct Installation
When two (2) or more controllers are used, keep a clearance of 50 mm or over in the
right and left directions between the controllers and a clearance of 100 mm or over in
the upper direction of each controller.
!
CAUTION
Keep a ventilation space on the lateral side of the controller to prevent stoppage
of the air vent holes. Also, keep the space equal to the length of the leg below
the bottom surface. Otherwise, the cooling ability will drop, causing faults.
DO NOT stack the controllers. DO NOT put objects on the top of each
controller.
POWER
EXT.SIGNAL
EXT.PC
MODE
SERVO
ON
SERVO
OFF
RUN STO P CYCLE
SELECT
AL AR M
RE SE T
UF1
UF2
LINE
USER
ALAR M
EMERGENCY
INT
EXT MANU
COM1
HOST
TCPRG
POD
TP
TP
disc on nec t
TOSHIBA MACHIN
Robot Controller
TS2000
Fig. 2.8 Controller ventilation space
50 mm or
over
50 mm or
over