3.2.4.2. FA06 (Command word 1)
bit Function 0 1 Note
0
Preset Speed
operation frequencies 1
1
Preset Speed operation
frequencies 2
2
Preset Speed operation
frequencies 3
3
Preset Speed operation
frequencies 4
Preset speed operation is disabled
or preset speed operation
frequencies (1-15) are set by
specifying bits for preset speed
operation frequencies 1-4.
(000: Preset speed operation OFF,
001-111: Setting of preset speed
operation frequencies (1-15))
-
4
Motor selection (1 or 2)
(THR 2 selection)
Motor 1
(THR1)
Motor 2
(THR2)
THR1: thr
THR2: f173
5 PI control Normal operation PI OFF -
6
Acceleration/decelerati
on pattern selection (1
or 2)
(AD2 selection)
Acceleration/dec
eleration pattern
1 (AD1)
Acceleration/dec
eleration pattern
2 (AD2)
AD1: acc, dec
AD2: f500, f501
7 DC braking OFF
Forced DC
braking
-
8 Jog OFF Jog run -
9 Forward/reverse Forward run Reverse run -
10 Run/stop Stop Run -
11 Coast stop command Standby Coast stop -
12 Emergency stop OFF Emergency stop Always enabled, “E” trip
13 Fault reset OFF Reset
No data is returned from the
inverter
14
Frequency priority
selection
OFF Enabled
Enabled regardless of the setting of
fmod
15
Command priority
selection
OFF Enabled
Enabled regardless of the setting of
cmod
Note: Set 0 to reserved bit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS1 Series and is the answer not in the manual?

Toshiba TOSVERT VF-AS1 Series Specifications

General IconGeneral
CategoryInverter
Input Frequency50/60 Hz ±5%
SeriesVF-AS1
Overload Capacity150% for 60 seconds
Input Voltage3-phase 200 to 240 VAC
Protection DegreeIP20
Ambient Temperature-10 to +50 °C (14 to 122°F) (Open type)
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Ground Fault
Braking UnitBuilt-in
CommunicationRS485
Power Range0.4 to 110 kW
Cooling MethodForced Air Cooling
Operating Temperature-10 to +50 °C (14 to 122°F) (Open type)
AltitudeUp to 1000 m
Output Voltage3-phase, voltage corresponding to input voltage

Related product manuals