a-2) Input signal connector HAND (TSL3100 Type-P)
Input circuit and example of connections
The INPUTCOM signal is the same as that of the
pins 6, 17 and 30 connected to the INPUT
connector on the controller front face.
As input signals, no-voltage contacts or transistor open collector inputs are used.
No-voltage contact specifications:
Contact rating: 24 VDC, 10 mA or over (circuit current: approx. 7 mA)
Minimum contact current: 24 VDC, 1 mA
Contact impedance: 100 or less
Transistor specifications:
Withhold voltage between collector and emitter: 30 V or over
Current between collector and emitter: 10 mA or over (circuit current: approx. 7 mA)
Leak current between collector and emitter: 100 µA or less
●
●
P24G
Contact or
transistor
Customer’s side
TSL3100
[Sink type (-Common)]
INPUTCOM