TRANSPORTATION AND INSTALLATION MANUAL 
 
143 
 
 
13.  Tool Interface (for the TS3100) 
13.1.  Tool wiring 
The robot is provided with the tool cable air pipe and arm 1 (1) (arm 2 (2) and arm 3 as 
options).   
Connection to external equipment from the robot controller can also be made without 
using the tool wiring in the robot arm. 
  Tool Signals (Controller Side) 13.1.1.
Eight  input  signals  for  components  such  as  sensors,  eight  control  signals  for 
components such as solenoid valves, 24 VDC, and 24 VDC GND are provided as tool 
signals  for  the  controller,  thus  enabling  the  wiring  from  the  controller  to  external 
equipment. (Cables between the controller and external equipment are optional.)    The 
signals are explained below. 
 
a-1)  Input signal connector HAND (TS3100    Type-N)   
Input circuit and example of connections 
●
●
P24V
●
[Source type (+Common)]
TS3100
Customer’s side
P24G
Contact or 
transistor