TRANSPORTATION AND INSTALLATION MANUAL
133
a-2) Input signal connector HAND (TSL3100E Type-P)
Input circuit and example of connections
The SYSINCOM signal is the same as that of the
pins 17 and 30 connected to the INPUT connector
on the controller front face.
As input signals, no-voltage contacts or transistor open collector inputs are used.
No-voltage contact specifications:
Contact rating: 24 VDC, 10 mA or over (circuit current: approx. 7 mA)
Minimum contact current: 24 VDC, 1 mA
Contact impedance: 100 or less
Transistor specifications:
Withhold voltage between collector and emitter: 30 V or over
Current between collector and emitter: 10 mA or over (circuit current: approx. 7 mA)
Leak current between collector and emitter: 100 µA or less
●
●
接点又は
トランジスタ
お 客様側
【Sink type(マイナスコモン)】
SYSINCOM
P24V
TSL3100E