EasyManua.ls Logo

Transcell Technology TI-1680 - Programming Set Points

Default Icon
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
STANDARD OUTPUTS
Each output tracks its corresponding set point. For example, Output 1 tracks Set Point 1; Output 2
tracks Set Point 2, etc. Note that the outputs continuously track the weight, i.e. they will re-fire when
the weight drops back below a set point.
For in-flight compensation, use the Cutoff delay (B6)
ACCUMULATION APPLICATION (F30 = 1)
The Print key is used to add a weight to the accumulator and increment the transaction counter. The
system weight must return to zero before another weight can be added.
The F1 key is used to print out the total and then reset the accumulator to zero.
Press the * key to briefly display the following information:
Transaction Counter => Gross Weight Total => Net Weight Total
Use the Over and Under keys to program in a Total Weight target for checkweighing.
REMOTE DISPLAY APPLICATION (F30 = 2)
Only the UNITS, ZERO, MODE AND TARE keys operate in this mode. No other keys will function.
All four outputs stay in CUTOFF state and the input is not recognized.
PIECE COUNT APPLICATION (F30 = 3)
IMPORTANT NOTE: The piece counting application cannot be used in commercial (NTEP)
applications.
This application is used to indicate the number of pieces of an item you have placed on the scale’s
platform. To ensure accuracy, the parts you are counting must be consistent in weight.
Upon power up, this mode works a lot like the Gross/Net/Tare mode. Use the F1 key to activate the
piece counting mode. Once in piece counting mode, the UNITS key becomes inactive.
Press the * key to briefly display the following information:
APW (Average Piece Weight)
To exit the piece counting mode and return to weighing mode, press the C/CE key.
Wt < SPx
Active
Cutoff
Wt SPx
Graph of O
UT
x versus Weight
for SPx

Table of Contents

Other manuals for Transcell Technology TI-1680

Related product manuals