APPENDIX C: DISPLAYED ERROR CODES
CODE MODE MEANING / POSSIBLE SOLUTION

Normal Operating
Mode
Gross Overload. A weight greater than the rated capacity has been
applied to the scale. Remove the weight from the platter or try re-
calibrating the scale. Otherwise, check for a bad load cell connection or
possible load cell damage due to overloading.
Err 0
Span Calibration
Mode (F17)
Keyed-in weight value is larger than full-scale capacity. Use a smaller test
weight or check keyed-in value.
Err 1
Span Calibration
Mode (F17)
Keyed-in weight value is less than 1% of full-scale capacity. Use a larger
test weight or check keyed-in value.
Err 2
Span Calibration
Mode (F17)
There is not enough load cell signal to produce the internal counts
necessary to properly calibrate the scale. First check all load connections.
Use F16 mode to view internal counts.
Err 3
All Modes Non-volatile memory read error. One or more setup parameters have
been lost.
Err 4
All Modes Non-volatile memory write error. Indicator needs service.
Err 5
Key-in Span
Calibration Mode
(F20)
You have attempted to enter a zero value for C1. Enter a known
calibration value greater than zero.
Err 6
Normal Operating
Mode
Keyboard tare value exceeds scales capacity. Please choose a tare value
equal to or less than scale capacity.
Err 9
Normal Operating
Mode
Span calibration value has been lost. Re-calibrate the scale.
Err 10
Normal Operating
Mode
Not in Gross mode (weigh in/weigh out mode only)
Err 11
Normal Operating
Mode
Negative weight not permitted (weigh in/weigh out mode only)

Table of Contents

Other manuals for Transcell Technology TI-1680

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Transcell Technology TI-1680 and is the answer not in the manual?

Transcell Technology TI-1680 Specifications

General IconGeneral
BrandTranscell Technology
ModelTI-1680
CategoryTouch Panel
LanguageEnglish

Related product manuals