EasyManua.ls Logo

Transcell Technology TI-1680 - Checkweighing and Batching Applications (F30)

Default Icon
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
APPENDIX A: SPECIFICATIONS
ANALOG SPECIFICATIONS
Full Scale Input Signal ±3.125 mV/V
Minimum Sensitivity - Non trade
0.3
µ
V / grad
Minimum Sensitivity - H-44
0.6
µ
V / grad
Input Impedance
30M
, typical
Internal Resolution Approximately 130,00 counts @ 1mV/V input
Display Resolution 50,000 display division max
Measurement Rate 10 Hz/80 Hz selectable
System Linearity Within 0.02% of FS
Calibration Method Software Calibration, with long term storage in EEPROM
Excitation Voltage
+5 VDC, 12 x 350
load cells
DIGITAL SPECIFICATIONS
Microcontrollers Silabs C8051F340
Program Memory
64K x 8, internal to
µ
C
SRAM:
2Kx 8, internal to
µ
C
EEPROM:
256 x 8, external to
µ
C, 8K x 8, external to
µ
Digital Filtering Software selectable
SERIAL COMMUNICATIONS
Serial Ports (Both) Full Duplex, selectable Baud rate
8 data bits, no parity, 1 stop bit
7 data bits, odd parity, 1 stop bit
7 data bits, even parity, 1 stop bit
7 data bits, no parity, 2 stop bits
CONTROL I/O
Outputs Four cutoff outputs, open collector design
Input One configurable logic level input for keyboard functions
OPERATOR INTERFACE
Display 1" (25 mm) 7-segment, LED, 6 Digit
Additional Symbols Net, Gross, Stable, Tare, lb, kg, Zero, Over, Under, Accept
Keyboard 24-key flat membrane switch
POWER
Mains 100-240 VAC, 50/60 Hz, 30W
DC Power Consumption
200mA + 15mA/350
Load Cell
Fuse (Internal) 1A 250V SLOW BLOW
ENVIRONMENTAL
Operating Temperature
–10° to +40
°
C (14° to 104° F)
Storage Temperature
-25° to +70
°
C (-13° to 158° F)
MECHANICAL
Overall Dimensions (L x W x H) 12.2" x 8.15" x 3.94" (310mm x 207mm x 100mm)
APPROVALS
NTEP CC # 10-078
Canada NOA # AM-5801

Table of Contents