Samba
19
CLEANING
Before cleaning, turn off the unit at the
isolation switch to avoid the shower being
accidentally switched on.
IT IS IMPORTANT TO KEEP THE SPRAYHEAD
CLEAN TO MAINTAIN THE PERFORMANCE OF
THE SHOWER. The hardness of the water will
determine the frequency of cleaning. For
example, if the shower is used every day in a
very hard water area, it may be necessary to
clean the sprayhead on a weekly basis.
Sprayplate removal
Remove the sprayhead from the hose. Unscrew
the bezel and remove the sprayplate complete
with ‘O’ ring from the sprayhead (fig.38).
Clean the sprayplate with a suitable brush or
preferably leave to soak overnight in a mild
proprietary descalent. Make sure all traces of
scale are removed and thoroughly rinse in clean
water afterwards.
Carefully refit the ‘O’ ring onto the sprayplate
and replace the sprayplate into the sprayhead.
Secure by screwing on the bezel.
Before replacing the sprayhead on the hose,
direct the hose to waste and switch on the
power back at the isolating switch.
Turn the temperature control to ‘1’.
Turn the power selector to ‘COLD’. This
operation will flush out any loose scale deposits
in the unit. Stop after about thirty seconds and
replace the sprayhead.
WARNING!
DO NOT use ‘powerful’ abrasive or
solvent cleaning fluids when cleaning
the shower as they may damage the
plastic fittings.
Fig.38