1 Shower
inoperable, no
water flow.
2 Water too hot.
3 Water
temperature cycling
hot/cool at
intervals.
4 Water too cool
or cold.
1.1 Interrupted power
supply.
1.2 Unit malfunction.
2.1 Not enough water
flowing through the
shower.
2.2 Blockage in supply.
2.3 Increase in ambient
water temperature.
3.1 Heater cycling on
temperature limiter.
4.1 Too much flow.
4.2 Water pressure
below minimum required
(see rating label).
4.3 Reduction in
ambient water
temperature.
4.4 Electrical
malfunction.
1.1.1 Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit breaker. If
it fails again, consult a qualified electrician.
1.1.2 Power cut. Check other appliances and if
necessary, contact local Electricity Supply Co.
1.2.1 Have unit checked. Ring Customer
Service.
2.1.1 Increase flow rate via temperature control.
2.1.2 Blocked sprayhead - clean or replace
blocked sprayplate in sprayhead.
2.2.1 Check if stop valves are fully open. Check
if a blockage in the inlet filter.
2.3.1 Readjust flow rate to give increased flow.
2.3.2 Select ‘economy’ power.
3.1.1 See 'Water too hot' causes 2.1, 2.2 and
2.3 and their appropriate action/cures. If it
continues, contact Triton Customer Service.
4.1.1 Reduce flow rate via temperature control.
4.2.1 Is water supply mains or tank fed ?
4.2.2 If tank fed, replumb to mains water
supply or see 4.2.4.
4.2.3 If mains fed, ensure that mains stopvalve
is fully open and that there are no other
restrictions in the supply while shower is in use,
or see 4.2.4.
4.2.4 Fit pump to give minimum pressure (see
rating label). Contact Customer Service for
advice.
4.3.1 Readjust flow rate to give reduced flow.
4.3.2 Select ‘high’ power.
4.4.1 Have unit checked by suitably qualified
electrician or contact Triton Customer Service.
FAULT FINDING
IMPORTANT: Switch OFF the electricity at the mains supply and remove the circuit fuse
before attempting any fault finding inside the unit.