Samba
2
ADVICE TO USERS
The following points will help you understand
how the shower operates:
a The electric heating elements operate at a
constant rate at your chosen power setting. It is
the rate of the water passing through the heater
unit which determines the shower temperature
at any given setting (the slower the flow the
hotter the water becomes, and the faster the
flow the cooler the water).
b During winter, mains water supply will be
cooler than in summer. Therefore the
temperature of the shower will vary between
seasons on any one setting of the temperature
control, e.g. if you have chosen setting number
6 as your preferred shower temperature in the
summer, you will have to increase that number
during winter by adjusting the temperature
control clockwise (which in effect slows the
water flow).
c The stabiliser valve minimises variations in
shower temperature during mains water
pressure changes. If changes in shower
temperature are experienced during normal use,
it will most likely be caused by the water
pressure falling near to or below the minimum
level. The drop in pressure may be due to water
being drawn off at other points in the house
whilst the shower is in use. If pressure drops
appreciably below the minimum, the heating
elements will automatically cut out.
If ever the water becomes too hot and you
cannot obtain cooler water, first check that the
sprayplate in the sprayhead has not become
blocked.
DO NOT place items such as soap or shampoo
bottles on top of the unit. Liquid could seep
through the joint between the cover and
backplate, and possibly damage the sealing
rubber.
Replacement parts can be ordered from Customer
Service. See ‘spare parts’ for details and part numbers.
Due to continuous improvement and updating,
specification may be altered without prior notice.
INTRODUCTION
This book contains all the necessary fitting and
operating instructions for your Triton electric
shower. Please read them carefully.
The shower installation must be carried out by a
suitably qualified person and in the sequence of
this instruction book.
Care taken during the installation will provide a
long, trouble-free life from your shower.
SPECIFICATIONS
Electrical
Nominal power Nominal power
rating at 240V rating at 230V
8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)
Water
Inlet connection – 15mm diameter.
Outlet connection – ½” BSP male thread.
Entry Points
Water – top, bottom, back, left or right.
Cable – top, bottom, back, left or right.
Materials
Backplate, cover, controls, sprayhead – ABS.
Sprayplate – Acetal.
Elements – Minerally insulated corrosion
resistant metal sheathing.
Dimensions
Height 305mm
Width 210mm
Depth 110mm
Standards and Approvals
Waterproof rating IPX4.
Complies with the requirements of current
British and European safety standards for
household and similar electrical appliances.
Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European
Community Directives (CE).