7
SPECIFICATIONS
check list
ELECTRICAL
Nominal power - rating at 240V Nominal power - rating at 230V
8.5kW – (40A MCB rating) 7.9kW – (40A MCB rating)
9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)
10.5kW – (45A MCB rating) 9.6kW – (45A MCB rating)
PLUMBING (see page 11 & 12 for water regulations)
Supply Source Mains pressure cold water only
Minimum running pressure and flow to the inlet
of the shower for full performance
100kPa (1.0 bar) at 8 litres per minute for
8.5kW & 9.5kW
150kPa (1.5 bar) at 11 litres per minute for 10.5kW
Maximum static pressure 1000 kPa (10 bar)
Maximum inlet temperature 28°C
Minimum inlet temperature 2°C
Inlet connection 15mm diameter
Outlet connection ½” BSP male thread
MATERIALS
ABS Backplate, cover, controls, shower head
Acetal Sprayplate
Minerally insulated corrosion resistant metal
sheathing
Elements
STANDARDS and APPROVALS
Splashproof rating IPX4
Safety Complies with the requirements of current
British and European safety standards for
household and similar electrical appliances
BEAB Complies with requirements of the British
Electrotechnical Approvals Board (BEAB)
CE/UKCA Meets with Compliance with European/UK
Community Directives
1
SECTIONSECTION