45
Problem
Possible Cause
Recovery Procedure
LCD panel is dark and keys are not
working
The cable between main PCB and LCD panel
is loose.
Check if the cable between main PCB and LCD is
secured or not.
LCD panel is dark but the LEDs are
light
The printer initialization is unsuccessful.
Turn OFF and ON the printer again.
Initialize the printer.
Ribbon encoder sensor doesn’t
work
The ribbon encoder sensor connector is loose.
Fasten the connector.
Ribbon end sensor doesn’t work
The connector is loose.
The ribbon sensor hole is covered with dust.
Check the connector.
Clear the dust in the sensor hole by the blower.
Cutter is not working
The connector is loose.
Plug in the connect cable correctly.