51
Irregular printing
* The printer is in Hex Dump mode.
* The RS-232 setting is incorrect.
* Turn off and on the printer to skip the dump mode.
* Re-set the Rs-232 setting.
Label feeding is not stable (skew)
when printing
* The media guides do not touch the
edge of the media.
* If the label is moving to the right side, please move the
label guide to left.
* If the label is moving to the left side, please move the
label guide to right.
Skip labels when printing
* Label size is not specified properly.
* Sensor sensitivity is not set properly.
* The media sensor is covered with dust.
* Check if label size is setup correctly.
* Calibrate the sensor by Auto Gap or Manual Gap
options.
* Clear the GAP/Black mark sensor by blower.
Wrinkle Problem
* Printhead pressure is incorrect.
* Ribbon installation is incorrect.
* Media installation is incorrect.
* Print density is incorrect.
* Media feeding is incorrect.
* Please set the suitable density to have good print
quality.
* Make sure the label guides touch the edge of the media
guide.
RTC time is incorrect when reboot the
printer
* The battery has run down.
* Check if there is a battery on the main board.
The printing position of small label is
incorrect
* Media sensor sensitivity is not set
properly.
* Label size is incorrect.
* The parameter Shift Y is incorrect.
* The vertical offset setting in the driver is
incorrect.
* Calibrate the sensor sensitivity again.
* Set the correct label size and gap size.
* Use DiagTool to fine tune the parameter of Shift Y.
* If using the software BarTender, please set the vertical
offset in the driver.