EasyManuals Logo

TSC TTP-247 User Manual

TSC TTP-247
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
30
calibrate gap or black mark sensor, depends on the sensor setting in the last print
job.
Please follow the steps below to calibrate the sensor.
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do
during the 5 blinks).
The LED color will be changed as following order.
Amber Æ red (5 blinks) Æ amber (5 blinks) Æ green (5 blinks) Æ
green/amber (5 blinks) Æ red/amber (5 blinks) Æ solid green
4. It calibrates the sensor and measures the label length and prints internal settings
then enter the dump mode.
Note:
Please select gap or black mark sensor by Diagnostic tool or by GAP or
BLINE command prior to calibrate the sensor.
For more information about GAP and BLINE command, please refer to TSPL2
programming manual.

Other manuals for TSC TTP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TTP-247 and is the answer not in the manual?

TSC TTP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Resolution203 dpi
Max Print Width4.09" (104 mm)
Processor32-bit RISC CPU
Weight2.5 kg
Max Print Speed7 ips
Memory8 MB SDRAM, 4 MB Flash
InterfaceUSB 2.0, Serial
Ribbon Capacity300 meters
Label Width1" (25.4 mm) ~ 4.33" (110 mm)
Label Thickness0.06 mm ~ 0.19 mm
Power SupplyExternal Universal Switching Power Supply
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Operating Humidity25% to 85%, non-condensing
CertificationsCE, FCC, UL, CCC