- 35 - 
 
5.5   Sensor 
 
This option is used to calibrate the selected sensor. We recommend calibrate the sensor 
before printing when changing the media. 
 
 
This option is used to set the media sensor type and calibrate 
the selected sensor automatically. Printer will feed 2 to 3 gap 
labels to calibrate the sensor sensitivity automatically. 
In case “Automatic” cannot apply to the media, please use 
“Manual” function to set the paper length and gap/bline size 
then scan the backing/mark to calibrate the sensor sensitivity. 
This option is used to set sensor sensitivity in fixed or auto. 
This option is used to set the maximum length for label 
calibration. 
This function can set the minimum paper length and maximum 
gap/bline length for auto-calibrate the sensor sensitivity. 
 
 
   
Menu  Sensor 
Auto Calibration 
Gap 
Black Mark 
Continuous 
Manual Setup 
Gap 
Black Mark 
Continuous 
Threshold Detect 
Auto 
Fixed 
Maximum Length 
Advanced