Programming Manual UTG900E Series
Instruments.uni-trend.com
:CHANnel1:BASE:PHAse 20
Set the output phase of channel 1 to 20°
:CHANnel1:BASE:PHAse?
The query returns 20
:CHANnel<n>:BASE:AMPLitude
Command Format:
:CHANnel<n>:BASE:AMPLitude { <amp>}
:CHANnel<n>:BASE:AMPLitude?
Function
Set the output amplitude of specified channel.
<amp> means voltage, unit is the specified one of current channel. 1mVpp ~ is the max.output in the
current load condition.
When the current unit is VPP, the current max.load=current load*20/ (50+current load)
<n>: Channel No, n value 1, 2.
Return Format
The query returns the output amplitude of specified channel, using scientific notation to return.
Example
:CHANnel1:BASE:AMPLitude 2
Set the output amplitude of channel 1 to 2V
:CHANnel1:BASE:AMPLitude?
The query returns 2e+0
:CHANnel<n>:BASE:OFFSet
Command Format
:CHANnel<n>:BASE:OFFSet { <voltage>}
:CHANnel<n>:BASE:OFFSet?
Function
Set the DC output offset of specified channel.
<voltage> means voltage, in “V” unit, range of 0~±max.DC of current load.
Max.DC of current load= current load*10/ (50+ current load)-current min.AC/2.
Min.AC is 2mVpp, value 0 in DC mode.
<n>: Channel No, n value 1, 2.
Return Format
The query returns the DC output offset of specified channel, using scientific notation to return.
Example
:CHANnel1:BASE:OFFSet 2
Set the DC output offset of channel 1 to 2V
:CHANnel1:BASE:OFFSet?
The query returns 2e+0
:CHANnel<n>:BASE:HIGH
Command Format
:CHANnel<n>:BASE:HIGH { <voltage>}
:CHANnel<n>:BASE:HIGH?
Function
Set the high signal output value of specified channel.