Overview
c02.fm
DECT IP Base Station Data
A31003-C1020-S100-03-7620, 12/2017
26 OpenScape Cordless IP V2, Service Documentation
2.3.1 Outdoor Case
A DECT IP base station must be installed in a weatherproof outdoor case to
guarantee radio coverage in outdoor areas, for example on factory sites. The
outdoor case is suitable for mounting on house walls, roofs or masts.
The outdoor case already used for the OpenScape Cordless base station BS4 is
also used for DECT IP base stations (part number: S30122-X7469-X2).
If using the DECT IP base station outdoors, lightning and overvoltage protection
must be provided and guaranteed for the DECT IP base station itself as well as
for the feeder into the DECT IP base station and the building. In compliance with
EN 61000-4-5, the power supply inlet on the DECT IP base station offers up to
0.5 KV overvoltage protection.
Figure 8 Outdoor case with DECT IP base station