pg. 14 UNINET DTF 1000
WIMS-SETUP
DO NOT CONTINUE UNTIL AFTER YOU HAVE FILLED INK TANKS AND PRIMED ALL DAMPERS!
Before powering on the WIMS, you need to have the white container at the top of the
printer filled with white ink.
The White Ink Management System is built into your printer. In order to power on the WIMS,
you need both the black and the white switches to be set to ON.
BEFORE TURNING ON THE PRINTER
The tanks should be installed in the following order:
1. Remove the cover on the left-hand side of the machine by removing the four Phillips head
screws, this will expose the CMYK ink tanks.
Before the screws are removed. After the 4 screws are removed.
2. Before filling the ink tanks, plug all small breather holes to avoid contamination in the
event a spill occurs. Once all breather holes are sealed, proceed with filling each ink tank
with its respective color. When filling, the only plug that should be open is the large one of
the color that is being filled, be sure to seal it before continuing on to the next color.
Example of what sealed breather holes