1.FUNCTIONAL DESCRIPTIONS
5
1-2-5. Signal Input/Output Terminal Board
This terminal board is used for input/output of control signals, SI/F data output, and
input of strain gauge sensor signals.
Terminal board Assignment
12 Two-wire serial interface SI/F for connecting printers and external display
from UNIPULSE.
This interface has no polarity and can connect up to three external devices.
Use parallel two-core cables or captire cables.
3 6 Output terminals of the high/low limit relays.
3・・・High limit relay N/O
4・・・High limit COM






㧿㧱㧾㧚
10
11
12
13
14
15
SER.N
1
11
12
13
14
15
2
3
4
5
6
7
8
9
10
SI/F
N/O
COM
High limit relay
Low limit relay
Hold input
COM
DZ input
Analog monitor output
Analog COM
EXC
SIG
EXC
SIG
SHIELD
N/O
COM
Strain gauge
Connect the shield
cable of the sensor.
sensor input