15.SPECIFICATIONS
90
15-6. Option
BCD Parallel data output (BCO)
RS-232C Interface (232)
D/A Converter (Please specify voltage and current output when making your order)
(DAC)
15-7. General Specifications
Power voltage - AC spec: 100V to 240V AC(+ 10% - 15%)
[Free power supply 50Hz/60Hz]
- DC spec: 12V to 24V DC ( ± 15%)
(Depending on the request at the time of order)
Power consumption - AC spec: 15W max.
- DC spec: 15W max.
Rush current (Typ) 20A, 2.5 msec.: 100V AC mean load state
(ordinary temperature, at cold-start time)
40A, 2.5 msec.: 200V AC mean load state
(ordinary temperature, at cold-start time)
Ambient conditions Temperature:Operation - 10 to + 40 ℃
Storage - 40 to + 80 ℃
Humidity:< 85%RH(non-condensation)
Dimensions 96W × 96H × 135D(mm)(excluding protrusions)
Panelcutout dimension 92 × 92 (mm)
Weight Approx.0.9kg
+ 1
- 0