5.SETTING OF FUNCTIONS
39
5-6. Digital Filter
This function minimizes instability of the weight value by calculating the average
frequency of the data converted from analog to digital. The frequency of the moving
average selected from OFF(0 or 1) ~ 64 times. A higher frequency will make a more
stable display with slower response.
A lower frequency will have quicker response but more unstable display.
1) Select setting mode 2.
2) Select digital filter.
Use and keys to set the digtal filter,
then use key to validate the setting.
To return to the indicated value display, press key.
FNC
SEL
DOWN
ENT
UP
DOWN
ENT
ESC
Setting of Digital Filter
5 64 times
4 32 times
3 16 times
2 8 times
1 4 times
0 OFF