6HOLD FUNCTION
55
Timing Chart
t1 Time from the short-circuiting of the hold input (OFF ON) to the display of the
peak hold value.
t2 Time until the A/D conversion of the analog value.
t3 Time from the input of the hold input (ON OFF) to the reset of the analog peak
hold value.
t4 The minimum tracking (resetting) time required for resetting the display of the
held value.
Time
t1
t2
t3
t4
Hold
input
Display and
BCD output
t1 MAX 25mS
t2 MAX 10mS
t3 MAX 25mS
t4 MIN 25mS
Indicated value
Sensor input