19.Threadthepull‐upcordthroughthetop
centerflap(Flap#6).
20.Replacethetemporarypinwiththereserve
pin,seatingittothedepthasshowntheleft.
21.
Sealreserveinaccordancewiththe
regulationsinyourareaandclosethepincover.
NOTE
Iftheforcenecessarytocloseflaps4and
5 seems excessive, the loop may be too
short.Useascaletodeterminehowmuch
forceisneededtoextractthepin;8lb(3.6
kg)to12lb(5.4kg)iscorrect.Ashortloop
canalsobendthereserveloopanchor.
WARNING
Makesure thattheSkyhooklanyard goes
directly from the RSL lanyard to the
Skyhookhardware,withoutgoingunderor
throughanything.(Exceptflap#2A)