Operation and function
01/21 FlowTimer+ Set 32
9.1.5 Changing the flow duration
The FlowTimer+ is preset at the factory to a maximum
continuous flow duration of 30 minutes. Experience has
shown that this is an optimum value for most applications.
If you want to adjust the pauseless flow duration to your needs, you
can easily change it:
Press the Set / Reset key (8) repeatedly until the desired flow
duration is shown on the display (10).
Then wait until the flow duration indicator (10) stops flashing.
The new flow duration is now stored and will be displayed
again after a restart or power failure.
After a flow duration of 120 min, all stages are displayed
simultaneously. This corresponds to an infinite flow
duration!
An infinite flow duration is indicated by a running light in
the flow duration display (10) after flashing.
WARNING
Tightness and water flow duration are no longer
monitored! Connected water sensors or additional
devices remain active in their protective functions.