EasyManuals Logo

UseTECH FlowTimer+ User Manual

UseTECH FlowTimer+
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Troubleshooting, maintenance
01/21 FlowTimer+ Set 46
10.2.4 Status display permanent green, but no
water
Green (duration)
After the installation of the system, they each have
water for about 60 seconds after pressing the Set/
Reset button.
After that, the water supply is shut off.
The status display shows green permanently.
The pressure sensor was installed in the water flow direction
upstream and not downstream of the FlowTimer+ shut-off
valve.
(see also point 6.4 "Installation of the pressure sensor")
If there is no incorrect installation, please take pictures of
your installation and send them to our customer service.
info@use-tech.de