Convert Server User Manual www.usriot.com
Jinan USR IOT Technology Limited 35 / 44 tec@usr.cn
Appendix A: Questions and Answers
Q1: How to configure transparent serial port application (TCP protocol) with
two Convert Servers?
Network structure as below figure:
Convert Server 1# Setting:
Works as AP mode; --See “Mode Selection Page”
LAN IP address: 10.10.100.254; --See “AP Interface Setting Page”
Network Protocal:TCP/Server, Port ID: 8899; -- See “Application Setting Page”
(Convert Server default setting);
Convert Server 2# Setting:
Works as STA mode; --See “Mode Selection Page”
WAN connection type: DHCP or Static IP (For this example:10.10.100.100)
--See “STA
Interface Setting Page”
Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Convert Server 1#’s LAN IP
address (10.10.100.254); -- See “Application Setting Page”
Notes: When Convert Server 2# works as STA mode, Convert Server’s WiFi interface works as
WAN port. Convert Server’s WAN IP address and LAN IP address shall be setting different segment.
So, Convert Server 2#’s LAN IP address must change to other segment; (For this sample, we
change to 10.10.99.254); --See “AP Interface Setting Page”
Figure 27 Configure Transparent Serial Port Connection (TCP)