EasyManua.ls Logo

USR IOT USR-WIFI232-630 - Q5: Two Servers STA Connection via AP

USR IOT USR-WIFI232-630
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Convert Server User Manual www.usriot.com
Jinan USR IOT Technology Limited 38 / 44 tec@usr.cn
Figure 32 Convert Server Network Protocol: TCP/Client
Protocol: UDP
No Server/Client selection required;
Application IP address required: it’s target device ‘s IP address;
Port ID required: 8899 (Default)
Figure 33 Convert Server Network Protocol: UDP
Q5: How to configure transparent serial port application: Two Convert
Servers all configured as STA and connection through AP?
Network structure as below figure:
Convert Server 1# Setting: ( We use USR-WIFI232-D2 as AP for this example)
Works as AP mode and all default setting;
Convert Server 2# Setting:
Works as STA mode; --See “Mode Selection Page”
WAN connection type: Static IP: 10.10.100.100; --See “STA Interface Setting Page”
Network Protocal:TCP/Server, Port ID: 8899; -- See “Application Setting Page”
LAN IP address: 10.10.99.254 (Different net segment with WAN port);
--See “AP Interface Setting Page”
Convert Server 3# Setting:
Works as STA mode; --See “Mode Selection Page”
WAN connection type: Static IP: 10.10.100.101; --See “STA Interface Setting Page”
Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Convert Server 2#’s WAN IP
address (10.10.100.100); -- See “Application Setting Page”

Table of Contents