Fault codes and software
24h on-call service phone: +358 (0)40 83 71 150
92
4
F8
Sys-
tem
faults
S7 1=Power
2=Power
1
3=Power
2
1=Board Control of the
charging relay
do not set.
Appears in the
NXP units, which
includes control
board VB00561.
Failure appears if the
system has external
relays which have longer
delay time than the used
program has. Check
external connections.
S8 1=Power
2=Power
1
3=Power
2
1=Unit
2=U
phase
3=V
phase
4=W
phase
Driver board
without auxil-
iary voltage.
Failure appears
in the unit sizes
FR9-FR14. Sig-
nal: ASIC-TRIN.
1. Check the phases U,
V, W.
Check the ASIC board
(VB00451).
3. Check connections
and connectors of the
optical fibres.
F9 S1 1=Power 1=Unit DC-voltage too
low in run-state.
S2 1=Power
2=Power
1
3=Power
2
1=Unit
S3 1=Power 1=Unit UV Fast Stop
F10 S1 1=Power
2=Power
1
3=Power
2
1 = Unit
S2 1=Power 1=Unit In regenerative
unit
F11 S1 1=Power 1=Unit
F12 S1 1=Power
2=Power
1
3=Power
2
1=Unit
TABLE 16.
System software fault codes
Code Sub
code
Module Sub
module
Explanation Fault mode

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range-10°C to +50°C (with derating above +40°C)
Cooling MethodAir-cooled, Liquid-cooled

Related product manuals