Fault codes and software
24h on-call service phone: +358 (0)40 83 71 150
98
4
F40 S1 1=Power
2=Power
1
3=Power
2
4=Con-
trol
5=Expan
der
6=Adapt
er
7=Star
coupler
1=Unit
2=Board
6=A slot
7 = Blot
8=C slot
9=D slot
10=E
slot
Checksum fault
in device infor-
mation. Only
after micropro-
cessor reset
S2 3=Power
2
1=Unit
2=Board
Power 2 not
equal to Power
1. Only after
microprocessor
reset
S3 7=Star
coupler
NXP2 required
with star cou-
pler. Only after
microprocessor
reset
S4 4=Con-
trol
Wrong device
data for Control
card or Control
unit. Only after
microprocessor
reset
S5 4=Con-
trol
2=Board Wrong size
eeprom on NXP
controlboard.
NXP0000V152 or
newer software
require 32kbyte
eeprom. Only
after micropro-
cessor reset
F41 S1 1=Power 1=Unit
TABLE 16.
System software fault codes
Code Sub
code
Module Sub
module
Explanation Fault mode

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit