The Connected options submenu (S6.8.6) shows the following information on the option board
connected to the frequency converter:
Page Content
E6.8.6.1 Option board
E6.8.6.1.1 Option board status
E6.8.6.1.2 Program version
Table 7-11. Connected options submenu
In this submenu you find information about the option board connected to the control board (see chapter 6.2)
You can check the status of the slot by entering the board submenu with the Menu button right and using the
Browser buttons. Push the Menu button right again to display the status of the board. The keypad will also
display the program version of the respective board when you push either one of the Browser buttons.
For more information on the expander board-related parameters, see Chapter 7.3.7.
Figure 7-16. Expander board information menu
7.3.6.6 AI mode
The parameter P6.9.2 selects the analogue input mode
Note! Make sure that the jumper selections correspond to the selections of this parameter. See Figure 6-16.
7.3.6.7 Fieldbus parameters
The parameters of Modbus protocol are only shortly described here. For further information, please
refer to Vacon NX Modbus Option Board User’s Manual. Please visit
http://www.vacon.com/support/nxdocuments.html.
Expander board communication status (I6.10.1)
With this function you can check the status of the RS 485 termination resistor
0 = Not connected
1 = Connected
ST OP
I/O term
READY
STOP
I/O term
READY