EasyManua.ls Logo

Vaisala WINDCAP WMT52 - General Unit Settings; Wind Configuration Settings; Table 19 General Unit Settings; Table 20 Wind Configuration Settings

Vaisala WINDCAP WMT52
143 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Guide ______________________________________________________________________
138 __________________________________________________________________M210925EN-B
General Unit Settings
0XF!0XF,f=11111111&11100010,o=AAC1DB1A,c=A263,
i=HEL___,n=A3430012,2=2528,3=3512 <cr><lf>
Wind Configuration Settings
0WF!0WF,g=A,l=N,t=A,0=273.00,1=273.01,2=273.00,3=273.00,4=2
73.00,5=273.00,a=45.1,b=50.2,u=54.9,v=63.1,x=65.1,y=65.1
<cr><l f>
Table 19 General Unit Settings
Field Character Field Name Description
f Factory options Selection of parameters
o Order code Ordering identity as delivered
(10 characters)
c Calibration date Y=2003, A, B,…=2005, 2006,
1..52 = week, 1...7, weekday
i Info Factory signature (10
characters)
n Device s/n A,B,...=2005,2006..., 1..52 =
week,
1...7 = weekday , 1...9999 =
serial number
2 2.5 V reference 2500mV (default)
3 3.5 V reference 3500mV (default)
Table 20 Wind Configuration Settings
Field Character Field Name Description
g Strategy A=All, N=North, E=East,
S=South
l Pulse length N=Normal,auto, A=Adjusted on
half, S=Short, E=Extended,
T=Test
t Single transducer mode A=All, N=North, E=East,
S=South
0..5 Zero adjustment 1...655.35 us (default 273.00 us)
a,b Detect level btw. N and E 0...100 % (default 70 %)
u,v Detect level btw. E and S 0...100 % (default 70 %)
x,y Detect level btw. S and N 0...100 % (default 70 %)

Table of Contents

Related product manuals