User’s Guide ______________________________________________________________________
72 ___________________________________________________________________M210925EN-B
8, Sensor and Data Message Settings, on page 95. The data is outputted 
when requested. In this mode all the commands presented in this 
chapter are available.
For changing the message parameters, units and other settings, see 
Chapter 8, Sensor and Data Message Settings, on page 95.
In the Native SDI-12 mode (aXU,M=S) the WMT52 is in idle state 
most of the time (power consumption < 1 mW). More power is 
consumed only during the measurements and data transmit requested by 
the host device. Especially, the wind measurement typically consumes 
60 mW average power (with 4 Hz sampling rate), throughout the 
averaging period. In the Continuous mode (aXU,M=R) the power 
consumption is determined by the internal update intervals of the sensor 
and wind averaging time. These have certain limits so very long 
measurement intervals cannot be achieved in this mode. Also the power 
consumption between the measurements is about three times that of the 
Native mode.
Address Query Command (?)
This command is used to query the address of the device on the bus.
If more than one sensor is connected to the bus, they will all respond, 
causing a bus collision.
Command format: ?!
The response:
a<cr><lf>
Example (device address 0):
where
? = Address query command
! = Command terminator
where
a = Device address (default = 0)
<cr><lf> = Response terminator