User’s Guide ______________________________________________________________________
56 ___________________________________________________________________M210925EN-B
Communication Setting Commands
Checking the Current
Communication Settings (aXU)
With this command you can request the current communication settings
of WMT52.
Command format in ASCII and NMEA 0183: aXU<cr><lf>
Command format in SDI-12: aXXU!
Example response in ASCII and NMEA 0183:
aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],L
=[L],N=[N],V=[V]<cr><lf>
Example response in SDI-12:
aXXU,A=a,M=[M],T=[T],C=[C],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>
NOTE
Hereafter the commands to be typed are presented in normal text while
the responses of the sensor are presented in italic.
where
a = Device address, which may consist of the following
characters: 0 (default) ... 9, A ... Z, a ... z.
XU = Device settings command in ASCII and NMEA 0183
XXU = Device settings command in SDI-12
<cr><lf> = Command terminator in ASCII and NMEA 0183
! = Command terminator in SDI-12
NOTE
You can add the Id information field in the supervisor data message to
provide identifying information in addition to the sensor address. See
section Supervisor Message on page 101. The information field is set
as part of the factory settings (see General Unit Settings on page 138).
You can only modify it using the Vaisala Configuration Tool.