EasyManua.ls Logo

Vaisala WINDCAP WMT52 - Page 86

Vaisala WINDCAP WMT52
143 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Guide ______________________________________________________________________
84 ___________________________________________________________________M210925EN-B
Command format: $--WIQ,MWV*hh<cr><lf>
The response format:
$WIMWV,x.x,R,y.y,M,A*hh<cr><lf>
The checksum to be typed in the query depends on the device identifier
characters. The correct checksum can be asked from WMT52 by typing
any three characters after the $--WIQ,MWV command.
where
$ = Start of the message
-- = Device identifier of the requester
WI = Device type identifier (WI = weather instrument)
Q = Defines the message as Query
MWV = Wind speed and direction query command
* = Checksum delimiter
hh = Two-character checksum for the query command.
<cr><lf> = Command terminator
where
$ = Start of the message
WI = Talker identifier (WI = weather instrument)
MWV = Wind speed and direction response identifier
x.x =
Wind direction value
1
1. Wind direction is given in relation to the devices north-south axis. An
offset value to the measured direction can be set, see section Chapter 8,
section Wind Sensor.
R = Wind direction unit (R = relative)
y.y = Wind speed value
M = Wind speed unit (m/s)
A = Data status: A = valid, V = Invalid
* = Checksum delimiter
hh = Two-character checksum for the response
<cr><lf> = Response terminator

Table of Contents