FAN 2 MINIMUM SPEED
When room temperature is at the Fan 2
relative set point, Fan 2 runs at minimum
speed set by this function. This value is
entered as a percentage of fan maximum
speed. The Fan 2 minimum speed is adjusted
in 2% increments from a minimum setting of
12% to a maximum setting of 100%.
Adjusting the minimum speed of Fan 2:
• rotate the selector dial to position (7),
•
rotate the adjuster dial counterclockwise to
decrease fan speed, clockwise to increase
it.
The minimum fan speed is displayed on the
ECS.
CHAPTER 3 - USER’S GUIDE
NOTE: Upon start-up, Fan 2 will run
at maximum speed for 4 seconds.
This feature helps to minimize the
risks of jams caused by ice.