EasyManua.ls Logo

VAT 613 Series - Tightening Torque Dns 40 - 50 Mm

VAT 613 Series
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Series 613 INSTALLATION
984360EC Edition 12.08.2022 19/
149
5.3.5 Tightening torque DNs 40 – 50mm
Tightening torques for ISO-KF flange connections depend on the type of seal which is used. Follow
recommendations of seal manufacturer.
5.3.5.1 ISO-KF Clamping connections
Clamping chain (example)
Valve size
ISO-KF ISO-KF
e.g.:
31032-KASA-0001
31034-KASA-0001
recommended
tightening torque
(Nm)
recommended
tightening torque
(lbs . ft)
DN40 / 1½ “ 5 3.7
DN50 / 2“ 6 4.5
Clamping device (example)
Valve size
ISO-KF ISO-KF
e.g.:
31032-KASE-0001
31034-KASE-0001
recommended
tightening torque
(Nm)
recommended
tightening torque
(lbs . ft)
DN40 / 1½ “ 12 9
DN50 / 2“ 12 9

Table of Contents