INSTALLATION Series
613
68/149
Edition 12.08.2022 984360EC
s:1
s:2
s:1
s:2
i:02
i:03
i:02
i:03
abcdef
Setup Sensor 1 and Sensor 2
a
Voltage Range
not used
b Display Range
not used
c
Display Unit
not used
d Gain Factor
0=0.1,1=0.13,2=0.18,3=0.23,4=0.32,5=0.42,6=0.56,7=0.75,8=1.0,9=1.33,A=1.78,
B=2.37,C=3.16,D=4.22,E=5.62,F=7.5,G=0.0001,H=0.0003,I=0.001,J=0.003,K=0.01,
L=0.02,M=0.05
e Sensor Type
not used
f
Zero Adjust:
0=disabled, 1=enabled
t:1
t:2
t:1
t:2
i:12
i:13
i:12
i:13
abcccc_
Setup Sensor 1 and Sensor 2
a Ramp Time
0=0.0,1=0.5,2=1.0,3=1.5,4=2.0,5=2.5,6=3.0,7=3.5,8=4.0,9=4.5,A=5.0 sec
b
Sensor Delay
0=0,1=0.02,2=0.04,3=0.06,4=0.08,5=0.1,6=0.15,7=0.2,
8=0.25,9=0.3,A=0.35,B=0.4,C=0.5,D=0.6,E=0.8,F=1.0 sec
c
Reserved