Page #30 background imageLoading...
Page #30 background image
Settings PLRF10C/15C-2.0en
30
Declination
compensation
Declination represents the
deviation between magnetic
north and grid north.
Declination:
•varies from location to
location
•varies from time to time
•is specified on most maps
To refer the azimuth angle to
grid north:
enter the local declination value
into the device.
To refer the azimuth angle to
magnetic north:
enter the value "0" into the
device.
Declination display
Click the azimuth three times in
rapid succession.
"dECL" appears briefly followed
by the current setting.
"OldC" is displayed before the
device switches itself off.
Positive value stands for east-
erly set declination. Negative
value stands for westerly set
declination.
L
The declination is
displayed in the
currently selected
angular unit
(see page 28)
The stored declination value:
•is reset to "0" when the
measurement units are
changed.
•is retained when the battery
is exhausted or replaced
•is factory set to "0"
3x