Connecting Probe/Sensor Wiring to Consoles TLS-350/ProMax/EMC Consoles
65
GROUNDWATER SENSOR INTERFACE MODULE - I.S. BAY
Figure 63. Groundwater Sensor Interface Module Wiring
Connecting Device
Connect sensor in the table below to the appropriate terminals on the Groundwater Sensor Interface module as
shown in Figure 63.
Device Wires Observe Polarity
4SITE Groundwater Sensor 3 Yes
GROUND
WATER
SENSOR
MAXIMUM SENSOR
OUTPUT RATINGS:
15 VDC
.15 AMP
FGWFGWFGWFGWFGW
11 22 33 44 55
GROUNDWATER SENSOR INTERFACE MODULE
consoles\gsimw.eps
Console
Not Used
FWG
Up to 5
Sensors
Sensor
#1
Sensor
#5
Attach Cable Shields to Ground
Lug Closest to Conduit Entry
FWG
Rigid Conduit
(enters Console
through an I.S. Bay
knockout)